Sas 7-1 Elisa Test Kit for Honey

Product Details
Customization: Available
Classification: Food Diagnostic
Trademark: kwinbon
Still deciding? Get samples of US$ 100/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
to see all verified strength labels (28)
  • Sas 7-1 Elisa Test Kit for Honey
  • Sas 7-1 Elisa Test Kit for Honey
  • Sas 7-1 Elisa Test Kit for Honey
  • Sas 7-1 Elisa Test Kit for Honey
  • Sas 7-1 Elisa Test Kit for Honey
  • Sas 7-1 Elisa Test Kit for Honey
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
KA01103H
HS Code
38229000
Production Capacity
50000pieces/Year

Product Description

 
 
 
 
Product Description
Competitive Enzyme Immunoassay Kit for Quantitative Analysis of
Sulfanilamide (SAs) Residue Detection (7-in-1)

1. Background
SAs are broadly applied bacteriophages, which are very important in controlling and curing animal disease. These drugs have very serious side effects and will lead to SAs resistance of some bacilus if they exist in human body for a long period. They also have potential carcinogenicity. Doc.235 of Ministry of Agriculture prescribes that the residue limit of SAs is 100mg/kg.
This kit is a new generation product for drug residue detection based on ELISA technology. It is fast, simple, accurate and sensitive. And it requires only 45min in one operation, which considerably minimizes work intensity and operation error. This kit is documented in Doc.558 of MOA in Oct.2005.
2. Test Principle
This kit is based on indirect-competitive ELISA technology. The microtiter wells are coated with coupling antigen. Drug residue including sulfamonomethoxine, sulfadiazine, sulfamethoxazole and sulfathiazole in the sample competes with the antigen coated on the microtiter plate for the antibody. After the addition of enzyme labeled anti-antibody, TMB substrate is used to show the color. Absorbance of the sample is negatively related to the SAs residing in it, after comparing with the Standard Curve, multiplied by the dilution factor, SAs residue quantity in the sample can be calculated.
3. Applications
This kit can be used in quantitative and qualitative analysis of SAs residue (SMM, SD/SDZ, SMZ, ST, PST, Sulfamethizole and Sulfapyridine) in tissue(chicken, pork, fish, shrimp), honey, milk and urine.
4. Cross-reactions
Sulfadiazine(SD or SDZ)................…100.0%
Sulfamonomethoxine (SMM)..............…137.0%
sulfamethoxazole (SMZ) ...............…335.0%
sulfathiazole (ST)......................846.5%
Phthalylsulfathiazole (PST)......…..........840.4%
Sulfamethizole ........................120%
Sulfapyridine.................…..........46%
Sulfamethazine .....................…..12.5%
Sulfadimethoxine .......................…<1%
Sulfaquinoxaline ........................<1%
Sulfamerazine.........…............................…<1%
5. Materials Required
5.1 Equipments
Microtiter plate spectrophotometer (450nm/630nm)
Shaker
Vortex mixer
Centrifuge
Analytical balance (inductance: 0.01g)
Graduated pipette: 10ml
Volumetric flask: 500ml
Polystyrene Centrifuge tubes:2ml, 50ml
Micropipettes: 20ml-200ml, 100ml-1000ml
250ml -multiple
5.2 Reagents
---- Acetonitrile (AR)
---- Ethyl acetate (AR)
---- N-hexane (AR)
---- Disodium hydrogen phosphate 12-hydrate (AR)
---- Sodium dihydrogen phosphate dihydrate (AR)
---- Sodium hydroxide (AR)
---- Concentrated hydrochloric acid(AR)
---- Deionized water
6. Kit Components
Microtiter plate with 96 wells coated with antigen
Standard solutions(6 bottles×1ml/bottle)
   0ppb, 0.5ppb, 1.5ppb, 4.5ppb, 13.5ppb, 40.5ppb
Spiking standard control:(1ml/bottle)   1ppm
Enzyme conjugate 7ml...….............. red cap
Antibody solution 7ml ...........…...…..green cap
Solution A 7ml........................white cap
Solution B 7ml ......…............... red cap
Stop solution  7ml ...........…....…yellow cap
20×Concentrated wash solution 40ml
.....................…..…..transparent cap
2×Extraction solution 50ml..............… blue cap
7. Reagents Preparation
Solution 1: 1M HCl
Measure 41.5ml concentrated hydrochloric acid and dilute to 500ml with deionized water.
Solution 2: 1M NaOH        
Dissolve 20.0g sodium hydroxide with deionized water and dilute to 500 ml.
Solution 3: pH=6 phosphate buffer solution
      Weigh 1.75g disodium hydrogen phosphate 12-hydrate, 10.52g potassium dihydrogen phosphate dihydrate, dilute with 500ml of deionized water.
Solution 4: Extraction solution
Dilute the 2×concentrated extraction solution with deionized water in the volume ration of 1:1, which will be used for sample extraction. This diluted solution can be conserved for 1 month at 4ºC.
Solution 5: Wash solution
Dilute the 20×concentrated wash solution with deionized water in the volume ration of 1:19, which will be used to wash the plates. This diluted solution can be conserved for 1 month at 4ºC.
8. Sample Preparations
8.1 Notice and precautions for the users before operation:
(a) Please use one-off tips in the process of experiment, and change the tips when absorb different reagent.
(b) Make sure that all experimental instruments are clean.
(c) Samples that are treated with other methods can be stored at 4ºC for 24 hours.
8.2 Milk(Raw milk, UHT milk)
Dilute 50µl of raw milk sample with 450µl of extraction solution(Solution 4), mix thoroughly.
Take 50ml of the prepared solution for assay.

Dilution factor:                10

3 Tissue(chicken, pork, fish, shrimp)
Homogenize the sample with homogenizer.
Weigh 2.0±0.05g homogenate to a 50ml polystyrene centrifuge tube,
Add 4ml of pH=6 phosphate buffer solution(Solution 3), vortex thoroughly, then add 6ml of ethyl acetate, shake for 1min, then centrifuge for separation: 5min / 3000g / ambient temperature.
Take 3ml of the supernatant liquid to a 10ml clean glass test tube, dry it with 50-60ºC water bath under nitrogen flow.
Add 1ml n-hexane ,vortex 30s to dissolve the dry leftover, and then add 1ml of extraction solution(Solution 4), vortex for 10s, centrifuge for separation: 5min / 3000g / ambient temperature.
Remove the upper layer of organic phase, take 50ml of the down layer of aqueous phase for assay.
Dilution factor:                1

8.4 Honey
Weigh 1.0±0.05g homogenate to a 50ml polystyrene centrifuge tube,
Add 1ml of 1M HCl(Solution 1), shake to dissolve the sample completely.
Incubate at 37ºC for 30min.
Add 1ml of NaOH(Solution 2), 1ml of pH=6 phosphate buffer solution(Solution 3), 2ml of acetonitrile and 6ml of ethyl acetate, shake for 1min, then centrifuge for separation: 10min / 3000g / ambient temperature.
Take 4ml of the upper layer of organic phase to a 10ml clean glass test tube, dry it with 50-60ºC water bath under nitrogen flow.
Add 0.5ml of extraction solution(Solution 4), vortex completely.
Take 50ml of the prepared solution for assay.
Dilution factor:                1

8.5 Urine
Take 50ml of the sample into a 2ml polystyrene centrifuge tube.
Add 150ml of the wash solution(Solution 5), mix thoroughly.
Take 50ml of the prepared solution for assay.
Dilution factor:                4
9. Assay process
9.1 Notice before assay:
9.1.1 Make sure all reagents and micro wells are all at room temperature (20-25ºC).
9.1.2 Return all the rest reagents to 2-8ºC immediately after used.
9.1.3 Washing the microwells correctly is an important step in the process of assay; it is the vital factor to the repetitiveness of the ELISA analysis.
9.1.4 Avoid the light and cover the microwells during incubation.
9.2 Assay Steps
9.2.1 Take all reagents out at room temperature (20-25ºC) for more than 30min, homogenize before use.
9.2.2 Get the microwells needed out and return the rest into the zip-lock bag at 2-8ºC immediately.
9.2.3 The diluted wash solution should be rewarmed to be at room temperature before use.
9.2.4 Number: Numbered every microwell positions and all standards and samples should be run in duplicate. Record the standards and samples positions.
9.2.5 Add standard solution/sample, enzyme conjugate and antibody: Add 50µl of standard solution(Kit provided) or prepared sample to corresponding wells. The add 50µl of enzyme conjugate(Kit provided), 50µl of antibody solution(Kit provided). Mix gently by rocking the plate manually and incubate for 30min at 25ºC with cover.
9.2.6 Wash: Remove the cover gently and pour the liquid out of the wells and rinse the microwells with 250µl diluted wash solution (solution 5) at interval of 10s for 4~5 times. Absorb the residual water with absorbent paper (the rest air bubble can be eliminated with unused tip).
9.2.7 Coloration: Add 50µl of solution A(Kit provided) and 50µl of solution B(Kit provided) to each well. Mix gently by rocking the plate manually and incubate for 15min at 25ºC with cover (see 12.8).
9.2.8 Measure: Add 50µl of the stop solution(Kit provided) to each well. Mix gently by rocking the plate manually and measure the absorbance at 450nm against an air blank (It's suggested measure with the dual-wavelength of 450/630nm. Read the result within 5min after addition of stop solution. ) (We can also measure by sight without stop solution in short of the ELIASA instrument)
10. Results
10.1 Percentage absorbance
The mean values of the absorbance values obtained for the standards and the samples are divided by the absorbance value of the first standard (zero standard) and multiplied by 100%. The zero standard is thus made equal to 100% and the absorbance values are quoted in percentages.

B --absorbance standard (or sample)
B0 --absorbance zero standard
10.2 Standard Curve
----To draw a standard curve: Take the absorbance value of standards as y-axis, semi logarithmic of the concentration of the SAs standards solution (ppb) as x-axis.
----The SAs concentration of each sample (ppb), which can be read from the calibration curve, is multiplied by the corresponding dilution rate of each sample followed, and the actual concentration of sample is obtained.
Please notice:
Special software has been developed for all data analysis, which can be provided on request.
11. Sensitivity, accuracy and precision
Test Sensitivity: 0.5ppb
Detection limit
Milk...............…................5ppb
Tissue...................…..........0.5ppb
Honey...................…..........0.5ppb
Urine...................…....….......2ppb
Accuracy
Milk...............…............….…95±25%
Tissue..................….........…85±25%
Honey..................….........…85±25%
Urine...............….............….95±25%
Precision
Variation coefficient of the ELISA kit is less than 10%.
12. Notice
12.1 The mean values of the absorbance values obtained for the standards and the samples will be reduced if the reagents and samples have not been regulated to room temperature (20-25ºC).
12.2 Do not allow microwells to dry between steps to avoid unsuccessful repetitiveness and operate the next step immediately after tap the microwells holder.
12.3. Homogenize each reagent before using.
12.4. Keep your skin away from the stop solution for it is the2M H2SO4 solution.
12.5 Don't use the kits out of date. Don't exchange the reagents of different batches, or else it will drop the sensitivity.
12.6 Storage condition:
Keep the ELISA kits at 2-8ºC, do not freeze. Seal rest microwell plates Avoid straight sunlight during all incubations. Covering the microtiter plates is recommended.
12.7 Indications for the reagents going bad:
Substrate solution should be abandoned if it turns colors.
The reagents may be turn bad if the absorbance value (450/630nm) of the zero standard is less than 0.5(A450nm<0.5).
12.8 The coloration reaction need 10-15min after the addition of solution A and solution B; But you can prolong the incubation time ranges from 20min to more if the color is too light to be determined., never exceed 30min,On the contrary, shorten the incubation time properly.
12.9 The optimal reaction temperature is 25ºC. Higher or lower temperature will lead to the changes of sensitivity and absorbance values.
13. Storage condition and storage period
     Storage condition: 2-8ºC.
Storage period: 12 months
 
Detailed Photos

 

Sas 7-1 Elisa Test Kit for Honey
Company Profile

 

Sas 7-1 Elisa Test Kit for HoneySas 7-1 Elisa Test Kit for HoneySas 7-1 Elisa Test Kit for HoneySas 7-1 Elisa Test Kit for Honey

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier