Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)

Product Details
Customization: Available
Classification: Food Diagnostic
Sep: 96tests
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
to see all verified strength labels (28)
  • Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
  • Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
  • Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
  • Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
  • Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
  • Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • Contact Us
Overview

Basic Info.

Model NO.
KB22603Y
Express
DHL or FedEx
Transport Package
Ice Bag with Foam Box
Trademark
kwinbon
Origin
China
HS Code
38229000

Product Description

Product Description

MilkGuard Rapid Test Kit for SABT+TEQL+SNKG+SMCF
1. Principle
This kit is based on competitive indirect colloid gold immunochromatography technology, in which drug residues in milk samples combines with the specific receptors or antibodies labeled with colloidal gold during flowing and inhibit its binding to ligands on NC membrane test line(T-line) or antigen-BSA conjugate.
Regardless of whether the milk samples contain drug residues or not, the control line(C-line) will be shown color that the tests are valid.
The test strip can be simultaneously matched with the colloidal gold analyzer to analyze the test results, extract the detection data and get the final detection result after data analysis.
2. Application
This kit is developed for rapid test of quinolones, sulfonamides, aminoglycosides, macrolides, lincoamines, florfenicol, monensin, colistin, bacitracin, trimethoprim.
3. Detection limit

Sulfonamides+Albendazole+Bacitracin+Trimethoprim,SABT
Sulfonamides LOD(ug/L) Sulfonamides LOD(ug/L)
Sulfadiazine 1.5-2 Sulfamethizole 2-2.5
Sulfamerazine 4-5 Sulfaquinoxaline 1.5-2
Sulfameter 1.5-2 Sulfamethoxypyridazine 4-5
Sulfamonomethine 1-1.5 Sulfaclozine 1.5-2
Sulfadimidine 4-5 Sulfamethoxazole 5-6
Sulfachloropyridazine 2-3 Sulfathiazole 12-15
Sulfadimethoxine 1.5-1.8 Sulfapyridine 20-25
Sulfisomidine 0.8-1 Sulfisoxazole 12-15
Sulfamethoxypyrazine 1.5-1.8 Sulfamoxol 25-30
Sulfapyrazole 12-15 Sulfacetamide 60-70
Sulfabenzamine 35-40 Sufadoxine 0.8-1
Sulfaphenazolum 30-35    
Other Medines LOD(ug/L) Other Medines LOD(ug/L)
Albendazole 20 Trimethoprim 1
Bacitracin 50    
Quinolones+Tylosin+Lincomycin+Erythromycin,TEQL
Quinolones LOD(ug/L) Quinolones LOD(ug/L)
Oxolinic acid 3.2-3.7 Ciprofloxacin 2.7-3.2
Levofloxacin 2.0-2.2 Nalidixic acid 3.0-3.4
Sarafloxacin 2.0-2.4 Enrofloxacin 3.2-3.7
Flumequine 2.4-2.8 Marbofloxacin 3.2-3.6
Difloxacin 2.5-3.0 Pefloxacin 3.2-3.6
Norfloxacin 2.7-3.0 Danofloxacin 3.0-4.0
Ofloxacin 2.7-3.2 Lomefloxacin 3.5-4.0
Enoxacin 3.0-3.5 / /
Macrolides LOD(ug/L) Lincoamines LOD(ug/L)
Erythromycin 4-6 Lincomycin 3
Azithromycin 4-5 / /
Tylosin 5 / /
Tilmicosin 5 / /
Gentamycin+Kanamycin+Neomycin+Spectinomycin,SNKG
Aminoglycosides LOD(μg/L) Aminoglycosides LOD(μg/L)
Gentamicin 10 Kanamycin 20
Neomycin 40 Spectinomycin 10
Spiramycin+Monensin+Colistin+Florfenicol,SMCF
Spiramycin 10 Monensin 5
Colistin 10 Thiamphenicol 0.2-0.3
/ / Florfenicol 0.1
4. Kit components
  1. Two test cards in one aluminum foil bag. 12 bags/box
There are four test strips per card, labeled as SABT, TEQL,SNKG, SMCF
  1. Kit insert     
  1. 4x8 microwell per aluminum foil bag, 3 bags/box
  1. Plastic pipette, 96pcs
  1. Instrument needed but not provided
Metal incubator(suggested product: Kwinbon Mini-T4) and Colloidal gold analyzer(Selected)
6. Assay operations
  1. Read the instructions carefully before experiment. Bring the test kit and samples to room temperature. Milk samples should be fully liquid without any agglomeration or deposition.
  2. Take test cards needed from the kit package, take out required wells, seal the aluminum foil in time and make proper marks. Please use these test cards within 1h.. The rest cards can be stored for future use.
Notice: one test cards corresponds to four gold colloidal microwells, please react one group per time and it can't be splitted. Reaction labeled as SABT, TEQL, SNKG, SMCF test cards, corresponds gold colloidal microwells labeled 1, 2, 3, 4, it is unmisplacable.
  1. Preheat the metal incubator to 45ºC.
  2. Place the mircrowells in the metal incubator, take 200ml of the test samples into the wells, then repeatedly absorb and drop for 5 times to mix the sample with the reagent in the wells completely. The mixture should be pink, and then start the timer.
  3. Incubate for 3min in the metal incubator (45ºC); take the test card cap, and insert the test card strips into the wells with the "Absorbent pad" end fully dipped in to the mixture.
(6)  Incubate for 6min in the metal incubator(45ºC) again. Take out the test card; judge the result according to Part 7. Notice: read the results within two minutes after reaction, otherwise, the results will be invalid.
Instrument interpretation:
Put on the test cards cap, insert the test card into colloidal gold analyzer, press TEST button, the colloidal gold analyzer will automatically read the results.
Notice: please read the test results within two minutes after the reaction, otherwise the analysis results will be invalid.
7 Results judgement
  1. Manual judgement:
  1. First check whether control line(C-line) show color, if not, means the test card is invalid.
  2. If control line(C-line) show color, judge the results as following:
Test line(T-line) and control line(C-line) color comparison Results judgement Results analysis
T-lineC-line Negative indicating the corresponding residue in sample is less than LOD of the kit.
T-line<C-line or T-line colorless Positive indicating the corresponding residue in sample is the same with the LOD of the kit or more than LOD of the kit.










Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)
T1= Sulfonamides;T2=Abendazole; T3=Bacitracin;T4= Trimethoprim

T5=Tylosin; T6=Erythromycin; T7=Quinolones; T8=Lincomycin
T9= Spectinomycin; T10=Neomycin;T11=Kanamycin;T12=Gentamycin
T13=Spiramycin; T14=Monensin; T15=Colistin; T16= Florfenicol
  1. Instrument interpretation:
7.2.1 Open colloidal gold analyzer, press Test button, select corresponding test project;
7.2.2 Connect the scanner, reader the QR code and check the batch number shown in the colloidal analyzer is consistent with the batch number on the package for assay;
7.2.3 Hand hold end out, insert the test card into colloidal gold analyzer holder, press test button, then read the test results;
7.2.4 If the screen of colloidal gold analyzer shows negative result, indicating the corresponding residue in sample is less than LOD of the kit.
If the screen of colloidal gold analyzer shows positive, indicating the corresponding residue in sample is the same with the LOD of the kit or more than LOD of the kit.
8.Notice
    1. Please do the assay following the instruction, do not touch the membrane of the strip.
    2. Please seal the luminum foil bag after taking out required test cards. Please don't open new test cards or colloidal gold unless it is used up.
    3. Don't mix different batches of test cards and colloidal gold microwells.
    4. The test card is used for only once; please do not use it repeatedly.
    5. This kit is only for screening test, positive result should be further confirmed with other method.

9.Specificity
1. Sulfonamides, Abendazole, Bacitracin and Trimethoprim test cards, has no cross reaction with the other three cards at the test concentration 500μg/L;
2. Tylosin, Erythromycin, Quinolones, Lincomycin test card, has no cross reaction with the other three cards at the test concentration 500μg/L;
3. Spectinomycin, Neomycin, Kanamycin, Gentamycin test card, has no cross reaction with the other three cards at the test concentration 500μg/L;
4. Spiramycin, Monensin, Colistin, Florfenicol test card, has no cross reaction with the other three cards at the test concentration 500μg/L.
10.Storage and valid date
The kit can be stored at 2-8ºC in dark cool place for 12 months.        Do not freeze.
Lot Number and date of production are printed on the package. 
 

Detailed Photos
Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)

 

Company Profile

Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)Milkguard Rapid Test Kit for Sabt+Teql+Snkg+Smcf (KB22603Y)Stuff

Kwinbon currently has more than 500 employees, including 18 doctors, 92 masters and 24 senior engineers. And also 46% of the employees are working on R&D.

Stock Market

NEEQ (National Equities Exchange and Quotations); Stock Code: 835044.

Facility

GMP (Good Manufacturing Practice) factory and SPF animal house. The cleanliness of producing department can reach above level 105.

Instruments

HPLC, GC, LC-MS/MS for test result calibration, which are expected to provide better quality control of our test products.
 

Contact Us

Contact me


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier