Product Details
Customization: Available
Express: DHL FedEx
Samples: Rice Peanut Feed
Still deciding? Get samples of US$ 5/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
to see all verified strength labels (28)
  • Ochratoxin a Residue Test Strip for Cereal
  • Ochratoxin a Residue Test Strip for Cereal
  • Ochratoxin a Residue Test Strip for Cereal
  • Ochratoxin a Residue Test Strip for Cereal
  • Ochratoxin a Residue Test Strip for Cereal
  • Ochratoxin a Residue Test Strip for Cereal
Find Similar Products

Basic Info.

Model NO.
KH00402Z
Transport Package
Ice Bag with Foam Box
Specification
50T
Trademark
kwinbon
Origin
China
HS Code
38229000
Production Capacity
5000000000 PCS

Product Description

Ochratoxin A Immunoaffinity columns
  1. Principle
The ochratoxin A immunoaffinity column is based on antigen- antibody-reaction technology, which makes the test highly specific, sensitive, rapid and simple to perform.
The columns contain a gel suspension of monoclonal antibody specific to the toxin of interest. Following extraction of the toxin the sample extract is filtered, diluted and passed slowly through the immunoaffinity column. Any toxin which is present in the sample is retained by the antibody within the gel suspension. The column is washed to remove unbound material and the toxin is then released from the column following elution with solvent. The final elution solution is for assay.
   It can reduce efficiently the sample impurity interference and improve the accuracy of test if it is combined with the HPLC, fluorescence and immunoassay.
  1. Sample
It can test the maize, soybean, peanut, wheat, barley, rice and finished feed.
  1. Required equipment
----Homogenizer
----Vortex mixer
----Sample bottle
----Volumetric flask: 10ml, 100ml
----Qualitative filter paper/Centrifuge
----Analytical balance (inductance: 0.01g)
----Graduated pipette: 10ml
----Injector: 10ml
----Volumetric flask: 250ml
----Rubber pipette bulb
----Micropipette: 100-1000ul
  1. Reagent
----Methanol (AR)
----Deionized water
  1. Sample preparations
----Homogenize the sample.
----Take 3.0±0.05g sample into sample bottle. Add 6ml of methanol and vortex for 2min or shake for 10min with table concentrator.
----Centrifuge: 5min/3000g at least/room temperature (20-25ºC). (If no centrifuge, it can also stand the solution and take 10ml of the supernatant to filter)
----Take 2ml (1g sample) of supernatant after centrifuge or filter and add 8ml deionized water. Mix completely and be for assay.
  1. Assay process
----Take out the columns in the 2-8ºC/35.6-46.4ºF and recover to room temperature (20-25ºC/68-77ºF).
----Connect the columns to the 10ml injector by the joint (picture 1). 
----Pipette 5ml (0.5g sample) of prepared solution into the injector→→use the injector to control the flow rate of the liquid to 1-2 seconds per drop through the column. 
---- Wash the column with 5ml deionized water for twice →→use the injector to control the flow rate of the liquid to 0.5-1 seconds per drop through the column. Finally drain the liquid in the column.
  • ----Elute with 1ml methanol→→use the injector to control the flow rate of
the liquid to 2-3 seconds per drop through the column. Collect all the eluent and be for assay.
Notice:
----Peristaltic pump can also be used to control the flow rate to through the column.
  • ----For a mass of test, using the pump flow operation can reduce the working time and intension.
7. Sample dilute ratio and recovery rate
Sample dilute ratio: 2 time
Recovery rate: ≥80%
8.Storage
Storage at 2-8ºC/35.6-46.4ºF. The period of validity is 12months.