• Rapid Test Strip for Fluoroquinolones
  • Rapid Test Strip for Fluoroquinolones
  • Rapid Test Strip for Fluoroquinolones
  • Rapid Test Strip for Fluoroquinolones
  • Rapid Test Strip for Fluoroquinolones
  • Rapid Test Strip for Fluoroquinolones

Rapid Test Strip for Fluoroquinolones

Environmental Protection: Yes
Certification: REACH
Color: White
Classification: Food Diagnostic
Function: Food Testing
Appearance: Liquid
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Beijing, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
KB00410Y
Transport Package
Foam Box with Ice Bag
Trademark
kwinbon
Origin
China
HS Code
38229000
Production Capacity
50000PCS/Year

Product Description

Product Description

MilkGuard Rapid Test Kit for Fluoroquinolones

  1. Principle
This kit is based on the specific reaction of antibody-antigen and immunochromatography. Fluoroquinolones antibiotics in the sample compete for the antibody with the antigen coated on the membrane of the test strip. Then after a color reaction, the result can be observed.
  1. Applications
This kit is used for rapid qualitative analysis of fluoroquinolones in raw milk and pasteurized milk.
  1. Detection Limit (LOD)
FQNS LOD(ppb)
Danofloxacin 18-20
Pefloxacin 6-8
Flumequine 10-12
Norfloxacin 6-8
Ofloxacin 7-8
Enoxacin 10-12
Oxolinic acid 20-30
Enrofloxacin 7-9
Ciprofloxacin 6-8
Sarafloxacin 7-9
Difloxacin 7-9
Marbofloxacin 6-8
lomefloxacin 7-9
  1. Kit components
  1. 8-well strip and 8 test strip in one bottle. 12 bottles / kit.
  1. Kit insert      
  1. microwell holder
  1. Plastic pipette, 96pcs
** Use one strip for one sample, the rest strips can be stored in the bottle for future use.
  1. Instrument needed but not provided
Dipstick reader(suggested product: Kwinbon K -reader)
Metal incubator(suggested product: Kwinbon Mini-T4)
  1. Assay operations
  1. Read the instructions carefully before experiment. Bring the test kit and samples to room temperature. Milk samples should be fully liquid without any agglomeration or deposition.
  2. Take bottles needed from the kit package, take out required wells and strips, and make proper marks. Please use these test strips within 1h. Seal the cap of the bottles. The rest strips can be stored for future use.
  3. Preheat the metal incubator to 45ºC.
  4. Place the mircrowells in the metal incubator, Take 200ul of the test samples into the wells, then repeatedly absorb and drop for 5 times to mix the sample with the reagent in the wells completely. The mixture should be pink, and then start the timer.
  5. Incubate for 3min in the metal incubator (45ºC); insert the test strips into the wells with the "Sample pad" end fully dipped in to the mixture.
  6. Incubate for 5min in the metal incubator(45ºC) again. Take out the strip; judge the result according to Part 7.(please read the result within 2min after the reaction finished)
  1. Results 
7.1 Manual Interpretation
There are 2 lines in the strip, Control line, Test Line, which are briefly used as "C", "T". The test results will depend on the color of these lines. The following diagram describes the result identification.
Negative(-) : Line T and Line C are both red, color of Line T is stronger than or similar to Line C, indicating the corresponding residue in sample is less than LOD of the kit. 
Positive(+) : Line C is red, color of Line T is weaker than Line C, indicating the corresponding residue in sample is higher than LOD of the kit. 
Invalid: Line C has no color, which indicates the strips are invalid. In this case, please read the instructions again, and redo the assay with new strip.
Note: If the result of the strip needs to be recorded, please cut the "Absorbent pad" end, and dry the strip, then keep it as file.
7.2 Instrument Interpretation
Interpret the result with Dipstick reader
  1. Specificity
The product shows negative at the level of 500μg/L of melaimine, sulfamethazine, erythromycin, lincomycin, tetracycliens etc.
  1. Storage
2-8ºC in cool dark place, do not freeze. The kit will be valid in 12 months. The lot number and expired date are printed on the package.
  1. Notice for operations
    1. Please do the assay following the instruction, do not touch the membrane of the strip.
    2. Please seal the bottle after taking out required strips.
    3. This strip is used for only once; please do not use it repeatedly.
    4. The different batch of the strips and wells can't use together.
    5. The dipstick reader should be cleaned termly.
    6. The result of this kit is only for reference. Please confirm according to the relevant standard methods of the country.
Detailed Photos

 

Rapid Test Strip for Fluoroquinolones
Company Profile

 

Rapid Test Strip for FluoroquinolonesRapid Test Strip for FluoroquinolonesRapid Test Strip for FluoroquinolonesRapid Test Strip for Fluoroquinolones

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
274
Year of Establishment
2008-12-30