Heavy Metal Lead Rapid Test (colloidal gold method)

Product Details
Customization: Available
Classification: Food Diagnostic
Assay Time: 6 Min
Still deciding? Get samples of US$ 100/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
to see all verified strength labels (28)
  • Heavy Metal Lead Rapid Test (colloidal gold method)
  • Heavy Metal Lead Rapid Test (colloidal gold method)
  • Heavy Metal Lead Rapid Test (colloidal gold method)
  • Heavy Metal Lead Rapid Test (colloidal gold method)
  • Heavy Metal Lead Rapid Test (colloidal gold method)
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • Contact Us
Overview

Basic Info.

Model NO.
Heavy Metal Lead Rapid Test
Trademark
kwinbon
Origin
China
HS Code
38229000

Product Description

Product Description

 

  1. Heavy Metal Lead Rapid Test (colloidal gold method)
    [Product Description]
    The heavy metal lead rapid test applies the principle of competitive inhibition immunochromatography, the heavy metal lead in the sample binds to the fluorescently labelled specific monoclonal antibody in the flow process, which inhibits the binding of the antibody and the heavy metal lead-BSA coupler on the detection line (T line) of the NC membrane, regardless of whether or not the heavy metal lead is contained in the sample, the labelled antibody to the heavy metal lead will be captured by the quality control antibody immobilized on the NC membrane in the process of chromatography and a red band will appear in the quality control region (C). Whether the sample contains heavy metal lead or not, the labelled heavy metal lead antibody will be captured by the quality control antibody immobilised on the NC membrane during the chromatographic process, and a red band will appear in the quality control region (C). The red band in the QC zone (C) is a criterion for determining whether the chromatography process is normal or not, and also serves as an internal control criterion for the reagents.
    [Minimum detection limit]
    15ppb
    [Scope of Application]
    This product is suitable for the detection of heavy metal lead in water quality.
    [Product Composition]
    1.Test cards: 20 sachets/box (each sachet contains one test card, one pipette, one reaction tube, one desiccant) 2.Instruction manual: 1 copy/box
    [Testing Procedure]
    1.Read the instructions completely before performing the test, remove the required amount of test reagent from the kit to return to room temperature (20 to 25°C), do not open the test reagent pouch until the test reagent has returned to room temperature. 2.After the test reagent and the sample to be examined are restored to room temperature (20~
    25ºC), carefully open the bag of the test reagent. 3.Pipette the sample to be tested to the mark (about 80ul), add it to the reaction tube, slowly suction until the test sample and the reaction reagent are well mixed, about 3-5 times, pipette the liquid in the reaction tube, slowly add it to the spiking hole of the test reagent (if it is a test strip, insert the test strip into the reaction tube), start the timer, and observe the result at 5 minutes. To ensure accuracy of results, do not read results after 10 minutes.
    [Interpretation of results]
    Negative Positive Invalid
    [Notes]
    1. The amount of liquid added during testing is as accurate and consistent as possible; 2. Confirm that the selection of test items is correct; 3. Please read the relevant results within the specified time; 4. Test strips should be used once within the shelf life; 5. Return the test strip and the sample to be examined to room temperature before use; 6. Do not touch the white film surface in the centre of the test strip, and discard for use if broken;
    [Storage and expiry date]
    1. storage temperature 2 -30°C, placed in a cool, dry place away from light, do not freeze; 2. This product is valid for24 months; 3. The date of production, expiry date and batch number are shown on the outer packaging
 
   
** Use one strip for one sample, the rest strips can be stored in the bottle for future use.
Detailed Photos

Heavy Metal Lead Rapid Test (colloidal gold method)

Company Profile


Heavy Metal Lead Rapid Test (colloidal gold method)Heavy Metal Lead Rapid Test (colloidal gold method)Heavy Metal Lead Rapid Test (colloidal gold method)Heavy Metal Lead Rapid Test (colloidal gold method)

 
Contact Us

Contact me

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier